Successful Water System Sanitization

This webinar will discuss common problems of sanitization process, the causes of sanitization failures and teach how to troubleshoot and take remedial actions with respect to material, construction methods, biofilm removal process and timing of sanitization.

$999.00
Introducing
Purchase using Webinar All-Access Pass
One User Unlimited access to all recorded webinars for 6 Months

Recorded Version Only

(PPT + Recorded Streaming Link)

$299.00
1x Person - Unlimited viewing for 6 Months (For multiple locations contact Customer Care)
rec Recorded Link and Ref. material will be available in My Account Section
Last Recorded Date: Feb-2019

Download File Only

(PPT + Recorded Training File)

$399.00
Downloadable file is for usage in one location only.
(For multiple locations contact Customer Care)
Downloadable link along with the materials will be emailed within 2 business days
Customer Care

Fax: +1-650-362-2367

Email: customercare@fdatrainingalert.com

Follow us:
Why Should You Attend:

For a water system to be successful various components play a role in it, like system design features, materials of construction, choice of sanitization chemicals and most importantly how they are used and how frequently the sanitization process is carried out.

If any of the above factors not done properly various problems can arise frequently like : microbial data trends showing increasingly higher counts in spite of remedial effforts, you are seeing P. aeruginosa or B. cepacia in your water system counts, then it is time to relook at your sanitization efforts and remedy to save cost, manufacturing time and quality of manufacturing.

This presentation focuses on the factors that can lead to water system sanitization success as well as failure so that the user can not only devise workable sanitization approaches, but also be able to recognize the early symptoms of a sanitization failure and troubleshoot the process for better optimization.

Areas Covered in the Webinar:
  • Material and construction limitations
  • Continuous vs intermittent sanitization
  • The importance of biofilm removal
  • How sanitants work (or don’t work)
  • When to sanitize
  • Common causes for sanitization failures and troubleshooting sanitization problems
Who Will Benefit:

This webinar will be valuable for all companies that operate Water for Injection(s) or Purified Water systems, particularly for those in FDA and EMA regulated industries, including Medical Devices, Diagnostics, Pharmaceuticals, and Biologics fields, as well as consumer products and cosmetics companies. The attendees who will benefit include:

  • Engineers involved in water system design
  • Utility operators and their managers involved in maintaining and sanitizing water systems
  • QA Managers and personnel involved in establishing water quality specifications and process control (Alert and Action) levels
  • QA Managers and personnel involved in investigations of excursions and preparing CAPAs
  • QC Managers and personnel involved in sampling, testing, and trending chem and micro data from water systems
  • Validation Managers and Personnel
  • Consultants and Troubleshooters
Instructor Profile:
T.C Soli T.C Soli

President, Soli Pharma Solutions, Inc.

T.C. Soli is a Ph.D. Microbiologist and President of Soli Pharma Solutions, Inc., and since becoming a full time consultant in 2004, has served consumer products and FDA-regulated industries with training and troubleshooting expertise covering water systems, sterilization, aseptic processing, microbiological and beta-lactam contamination control, microbiological laboratory operations. He has served as a pharmaceutical expert witness in several water-related product contamination litigations. Prior to full time consulting, he had 25 years of diverse "Big Pharma" operating company experience. During his 39 year career he has lectured extensively at conferences, authored numerous papers and several book and industry guide chapters related to water system microbiology for PDA and ISPE publications. He is in his 18th year as a volunteer and member of USP Expert Committees associated with pharmaceutical water and has co-authored everything currently written in USP regarding water, including all the water monographs and associated test and informational chapters.

Refund Policy

Registrants may cancel up to two working days prior to the course start date and will receive a letter of credit to be used towards a future course up to one year from date of issuance. FDATrainingAlert would process/provide refund if the Live Webinar has been cancelled. The attendee could choose between the recorded version of the webinar or refund for any cancelled webinar. Refunds will not be given to participants who do not show up for the webinar. On-Demand Recordings can be requested in exchange.

Webinar may be cancelled due to lack of enrolment or unavoidable factors. Registrants will be notified 24hours in advance if a cancellation occurs. Substitutions can happen any time.

If you have any concern about the content of the webinar and not satisfied please contact us at below email or by call mentioning your feedback for resolution of the matter.

We respect feedback/opinions of our customers which enables us to improve our products and services. To contact us please email customercare@fdatrainingalert.com call +1-888-771-6965 (Toll Free).

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product! Write review

You Recently Viewed